remote
Configuration of manager to listen for events from the agents.
Options
connection
Specifies a type of incoming connection to accept: secure or syslog.
Default value |
secure |
Allowed values |
secure, syslog |
port
Specifies the port to use to listen for events.
Default value |
1514 if secure, 514 if syslog |
Allowed values |
Any port number from 1 to 65535 |
protocol
Specifies the protocol to use. It is available for secure connections and syslog events.
Default value |
udp |
Allowed values |
udp, tcp |
Note
It is not possible to use both protocols simultaneously.
allowed-ips
List of IP addresses that are allowed to send syslog messages to the server (one per line).
Default value |
n/a |
Allowed values |
Any IP address or network |
Note
It is necessary to list at least one IP address when using the syslog connection type.
deny-ips
List of IP addresses that are not allowed to send syslog messages to the server (one per line).
Default value |
n/a |
Allowed values |
Any IP address or network |
local_ip
Local ip address to use to listen for connections.
Default value |
All interfaces |
Allowed values |
Any internal ip address |
ipv6
Local ipv6 address to listen for connections.
Default value |
n/a |
Allowed values |
Any IPv6 address |
Example of configuration
<remote>
<connection>syslog</connection>
<port>514</port>
<protocol>udp</protocol>
<allowed_ips>192.168.1.0/24</allowed_ips>
<local_ip>192.168.1.5</local_ip>
</remote>
<remote>
<connection>secure</connection>
<port>1514</port>
<protocol>udp</protocol>
</remote>